FP-45

FP-45

 

 

TECHNICAL DATA SHEET

PRODUCT NAME: FP-45

SYNONº CAS: 64742-47-8

NUMBER UN : 1268

DESCRIPTION: Aliphatic solvent. Distillates (Petroleum)

SPECIFICATIONS

PHYSICOCHEMICAL PARAMETER MIN MAX METHOD
COLOR SAYBOLT +28 N/A ASTM D-6045
SPECIFIC GRAVITY (25°C) 0,78 0,82 ASTM D-1298
DISTILLATION

Initial Boiling Point °C (IBP)

Final Point °C (FP)

160

N/A

N/A

230

ASTM-D-86

ASTM-D-86

FLASH-POINT (°C) >45 N/A ASTM D-93
WATER (ppm) N/A 100 ASTM D-6749
VISCOSITY (cst @ 40 °C ) 0,8 N/A ASTM D-445
SULFUR CONTENT (ppm) N/A 20 ASTM D-5453
AROMATICS (% Vol) N/A 1 ASTM D-6591

 

Applications: Used in surface cleaners (wood and formica) .Base for industrial lubricants in textile machineries and / or food processing. Industrial degreasers.

Elaboration Date:

01-2015

Last Review Date:

06-2018

DesignedBy:

Lab Quality Analyst

Approved By:

Technical Director

 

 

 

1.  SECTION 1. PRODUCT IDENTIFICATION

 

 

 

                                                                   PRODUCT NAME:                          FP-45

                                                                            SYNONYMS:                        Petroleum Distillates, Mineral Spirit, Mineral Solvent, Mineral

                                                                                                                                  Spirits, aliphatic solvent.

 

                                                                                                       COMPANY:                       Benzoatos de Venezuela Benzoven CA

 

                                                                                ADDRESS:                        Calle Interna Parque Industrial del Calzado parcela # 75 Zona Ind.                                                                                                                                 Santa Cruz Aragua. Zona Postal 2123 

                                                                                          CITY:                        Santa Cruz de Aragua, Edo. Aragua. Venezuela

                                                                                    PHONES:                        +58 243-2140597/ +58 243-2610861 (Venezuela)

                                                               EMERGENCY NUMBER:                         +58 243 2140591

 

 

 

 

 

2.  IDENTIFICATION OF HAZARDS

 

 

 

 

                   NFPA classification:

Health:            Category 1

inflammability: Category 2

Reactivity:          Category 0

GHS Classification:

Aspiration hazard: Category 1

Chronic aquatic toxicity: Category 2

Flammable liquid: Category 3

Skin irritant: Category 2

        Sign: Caution

 

Eyes: May cause moderate irritation

 

Ingestion: May cause lung damage if ingested.

 

Inhalation: Vapors may be slightly irritating. They can cause dizziness and vomiting.

 

Skin: May cause moderate skin irritation. Repeated exposure can cause dry skin.

 

 

 

3. INFORMATION OF THE INGREDIENTS

 

 

 

Chemical name

Chemical name

CAS-No.

Concentration  [%]

DISTILLATES OF HYDROTRATE PETROLEUM

 

64742-47-8

 

100%

 

 

 

 

4.  MEASURES FOR FIRST AID

 

 

 

   Inhalation

  Immediately move the victim to fresh air. Seek medical attention.

Ingestion

  Do not induce vomiting. Seek medical attention immediately.

Skin contact

Remove contaminated shoes and clothing. Clean the affected area with plenty of water.

eyes

If the eyes become irritated, move the victim to fresh air. Wash eyes with plenty of water. If symptoms persist, seek medical attention.

 

 

5.  FIRE MEASURES

 

 

 

Clasification of

Flammability of NFPA

Class-II liquid fuel according to NFPA

Flash Point

Closed cup: 42°C (108°F). (Tagliabue)

Lower Flammability     Limit

AP 0.5 %                     Upper Flammability Limit                       AP 6 %

Temperature of

Auto ignition

230°C (446°F)

Products of

Risky Combustion

Carbon dioxide, carbon monoxide, vapors, fumes, and / or unburned hydrocarbons

Special Properties

Liquid Fuel! This product generates vapors when heated above ambient temperatures. Vapors can cause a sudden fire. Vapors can travel to the ignition source and generate a flame. Use only with adequate ventilation.

 

 

 

 

6.  MEASURES AGAINST SPILLS OR ACCIDENTAL LEAKS

 

 

Take adequate precautions to protect your own health and safety before attempting to clean or control a spill

.

Fuel Liquid! The spill can cause a fire hazard, but this material will not ignite easily. Evacuate all non-essential personnel from the immediate area. Eliminate all sources of ignition. Stop the leak, if you can do it without risk. Do not touch or walk through spilled material. Avoid entering channels, sewers, basements, or closed areas. Absorb or cover with dry earth, sand, or other non-flammable material and transfer to waste containers.

For large spills, secure the area and control access. In an urban area, clean up the spill as soon as possible; In natural environments, follow the cleaning recommendations of an environmental specialist. Collect the liquid to be recycled and / or discarded. Collect any excess material with absorbent pads, sand, or other inert, absorbent and non-flammable materials. Place in appropriate waste containers, for later disposal. Comply with all laws and regulations.

 

7. HANDLING AND STORAGE

 

 

 

        

                    DRIVING

Keep containers closed, and do not handle or store them near heat, sparks, or any other potential source of ignition. DO NOT come in contact with oxidizing materials. Use only with adequate ventilation and personal protection. Avoid contact with eyes, skin and clothing. Prevent contact with food and tobacco products. Use gloves made of waterproof materials and protective clothing, if direct contact is anticipated. Use the appropriate respiratory protection. DO NOT pressurize, cut, weld, puncture or grind containers. Empty containers may contain product residues that can ignite.

        STORAGE

Store in a cool, dry, well-ventilated place. Store only in approved containers. Do not store with oxidizing agents. Do not store at elevated temperatures or in direct sunlight. Protect containers against physical damage. The storage area must maintain OSHA requirements

 

                

            8.  EXPOSURE CONTROLS AND PERSONAL PROTECTION

 

 

 

 

 

 

Engineering Controls

Provide ventilation or other engineering controls to maintain vapor or mist concentrations within the applicable workplace exposure limits listed below. A station for emergency eye lava and safety shower should be placed near the work site.

Protective equipment

                Personal

Personal protective equipment must be selected based on the conditions under which this product will be used. The minimum requirements for personal protective equipment: Protective gloves, Suitable clothing, Protective lenses

Protection for Eyes

Safety glasses equipped with side shields are recommended as minimum protection in industrial locations. An emergency eye wash station and safety shower should be placed near the work site.

Protection for

Hands

Avoid skin contact. Use gloves for industrial use. Wash hands and other exposed parts of the skin with mild soap and water before eating, drinking, smoking, using the bathroom, or when leaving work.

Protection for

Body

Avoid contact with skin. Wear non-flammable long-sleeved clothing while working with flammable and combustible liquids.

Respiratory protection

Use a multipurpose (US) or cartridge type respirator (EN 14387). Respirators must be used in accordance with OSHA requirements (29CFR 1910.134)

   

       

 

 

 

 

9.  PHYSICAL AND CHEMICAL PROPERTIES

 

 

Appearance: Transparent

 

Physical State: Liquid

 

Odor: Low Odor (hydrocarbon)

 

pH: without data

 

STEAM PRESSURE, mmHg at 25 ° C: <1

 

GRAV. ESP. OF STEAM, at 1 atm (Air = 1):> 1

 

SOLUBILITY IN WATER: not soluble

 

SPECIFIC GRAVITY at 25 ° C: 0.78-0.82

 

Evaporation Rate (nBuAc = 1): <1

 

EVAPORATION INDEX (n-BuAc = 1): <1

 

EBULLITION POINT ° C:> 170 approx.

Flash Point:> 113 ° F /> 45 ° C ASTM D-93 (Closed Cup)

 

Flammability%: no data

 

 

 

 

10. STABILITY AND REACTIVITY

 

 

 

Chemical Stability: Stable under ordinary conditions of use and storage. Conditions to avoid: Keep away from any source of ignition and oxidizing agents. Materials to Avoid: Strong oxidizers.

Hazardous decomposition products: No additional hazardous products identified

 

Hazardous Polymerization: Not expected to occur.

 

 

 

11.   TOXICOLOGICAL INFORMACION

 

 

No definitive information is available on carcinogenicity, mutagenicity, target organs or developmental toxicity.

 

 

 

 

12. ECOLOGICAL INFORMATION

 

Not rated

 

 

13.  DISPOSAL CONSIDERATIONS

 

 

The conditions of use can cause this material to become a «hazardous waste», as defined by federal and state regulations. It is the user’s responsibility to determine if the material is a hazardous waste subject to RCRA at the time of disposal. The transport, storage and final disposal of the waste material must be carried out in accordance with the RCRA regulations (40 CFR 260 to 40 CFR 271).

 

14.  INFORMATION ON TRANSPORTATION

 

 

 

 

Risk Classification: Combustible Liquid

DOT: UN NUMBER 1268

Signboard: PETROLEUM DISTILLATE, N.O.S

CLASSIFICATION: 3

IMDG: UN number: 1268 ; CLASS 3 group 3

EMS No .: F-E, S-E

Signboard: Petroleum Distillates, N.O.S

Marine Pollutant: no

IATA: UN number: 1268 class; CLASS 3

Signboard: Petroleum Distillates, N.O. S

 

 

15.  REGULATORY INFORMATION

 

 

 

This security sheet complies with the legal regulations of:

Mexico: NOM-018-STS-2000

Guatemala: Labor Code, decree 1441

 

 

Honduras: Executive Agreement No. STSS-053-04

 

Costa Rica: Decree No. 28113-S

 

Panama: Resolution # 124, March 20, 2001

 

Colombia: NTC 445 July 22, 1998

 

Ecuador: NTE INEN 2 266: 200

 

 

16.  INFORMACION ADICIONAL

 

 

Review: 1

 

Date: 06/2018

SDS Number: BNZ-FP45-01

Status: Final

Elaboratedby: Approvedby:
Quality Control Analyst Technical Director
Contact Us

No estamos aquí en este momento. Pero puede enviarnos un correo electrónico y nos comunicaremos con usted lo antes posible.